SEADM

Sociedad Europea de Análisis Diferencial de Movilidad SL

Our analytical solutions,
your new edge
Contact us
  • Home
  • Products
    • DMAs for molecules and nanoparticles
      • Half-Mini
      • Mobility Front End
      • DMA P5
      • Tandem DMA
    • Vapor analysis and detection
      • LFSESI
        (patented SESI for MS)
      • Vapor Analysis Front End
        (LFSESI-DMA for MS)
      • Vapor Analysis System
    • Technological modules
      • DMA cells
        • Planar DMA cell
        • Cylindrical DMA cell (Half Mini)
        • HEPA filter 1 nm
      • Ionization sources
      • Others
        • High Volume Sampler
        • Variable temperature desorber
        • Mobility Spectra Processor Software (MSPS)
  • Applications
    • Atmospheric aerosols
    • Health
    • Life sciences
    • Food
    • Environment
    • Security
    • Nanoparticle materials
  • Customer Reviews
  • Technologies and Patents
  • Publications
  • Company
    • Team
    • News and Press Releases
    • Awards
    • Follow SEADM
      • YouTube
      • Twitter
    • Quality Policy
    • Contact and directions
  • Contact us

Publications

Scientific Journals

The following list includes the publications produced by SEADM personnel in Scientific Journals. Publications exclusively by customers can be found in the different product pages.

2020

  1. Piñero M.Y., Amo-González M., Delgado R., Ruíz L., Arce L., Fernandez de la Mora G.
    Chemical Fingerprinting of Olive Oils by Electrospray Ionization-Differential Mobility Analysis-Mass Spectrometry: A New Alternative to Food Authenticity Testing.
    J. Am. Soc. Mass Spectrom., 2020

2019

  1. Amo-González M., Pérez S., Delgado R., Arranz G., Carnicero I.
    Tandem Ion Mobility Spectrometry for the Detection of Traces of Explosives in Cargo at Concentrations of Parts Per Quadrillion.
    Analytical Chemistry, 2019
  2. McCulloch R., Amo-González M.
    Rapid detection of explosive vapors by thermal desorption atmospheric pressure photoionization differential mobility analysis tandem mass spectrometry.
    Rapid Commun Mass Spectrom. (2019) 33, 1455–1463.

2018

  1. Amo-González M., Pérez S.
    Planar Differential Mobility Analyzer with a Resolving Power of 110.
    Analytical Chemistry, 2018, 90, 11, 6735-6741
  2. Tejero A., Dev Singh K., Nowak N., Gaugg M. T., Bruderer T., Zenobi R., Martinez-Lozano Sinues, P.
    Real-Time Monitoring of Tricarboxylic Acid Metabolites in Exhaled Breath.
    Analytical Chemistry 2018, 90, 11, 6453-6460.
  3. Amo-González M., Carnicero I., Pérez S., Delgado R., Eiceman G. A., Fernandez de la Mora G., Fernandez de la Mora J.
    An IMS-Fragmenter-IMS analog of a triple quadrupole for high-resolution ion analysis at atmospheric pressure.
    Analytical Chemistry, 2018, 90, 11, 6885-6892.
  4. Zamora D., Amo-González M., Lanza M., Fernandez de la Mora G., Fernandez de la Mora J.
    Reaching a Vapor Sensitivity of 0.01 Parts Per Quadrillion in the Screening of Large Volume Freight.
    Analytical Chemistry, 2018, 90, 4, 2468-2474.

2017

  1. R. McCulloch, A. Alvaro, A. M. Astudillo, J. C. del Castillo, M. Gómez, J. M. Martín, M. Amo-González
    A novel atmospheric pressure photoionization – Mass spectrometry (APPI-MS) method for the detection of polychlorinated dibenzo P- dioxins and dibenzofuran homologues in real environmental samples collected within the vicinity of industrial incinerators.
    International Journal of Mass Spectrometry. 2017, 421, 135-143.
  2. Tejero Rioseras A.; García Gómez D.; Ebert B. E.; Blank L. M.; Ibáñez A. J.; Martínez-Lozano, P.,
    Comprehensive Real-Time Analysis of the Yeast Volatilome.
    Scientific Reports 7, Article number: 14236. Oct 2017.
  3. Fernandez de la Mora J.,
    Expanded size range of high-resolution nanoDMAs by improving the sample flow injection at the aerosol inlet slit.
    Journal of Aerosol Science, 2017, 113, 265-275
  4. Tejero Rioseras A., Gaugg M., Martinez-Lozano Sinues, P.
    Secondary electrospray ionization proceeds via gas-phase chemical ionization.
    Analytical methods, 2017, 9 (34).
  5. Fernandez de la Mora J., Perez-Lorenzo L.J., Arranz G., Amo-González M., Burtscher H.
    Fast high-resolution nanoDMA measurements with a 25 ms response time electrometer
    Aerosol Science and Technology, 2017, 51, 6, 724-734.
  6. Amo-González M., Fernandez de la Mora J.
    Mobility Peak Tailing Reduction in a Differential Mobility Analyzer (DMA) Coupled with a Mass Spectrometer and Several Ionization Sources.
    Journal of the American Society for Mass Spectrometry, 2017 28: 1506.
  7. Fernández de la Mora, J., Barrios-Collado, C.
    A Bipolar electrospray source of singly charged salt clusters of precisely controlled composition.
    Aerosol Science and Technology, Vol. 51 , Iss. 6,2017 (Feb 2017).

2016

  1. Gaugg, T. M.; García-Gomez, D.; Barrios-Collado, C.; Vidal-de-Miguel, G.; Vidal-de-Miguel, G.; Zenobi, R.; Martínez-Lozano-Sinues, P.
    Expanding metabolite coverage of real-time breath analysis by coupling a universal secondary electrospray ionization source and high resolution mass spectrometry – a pilot study on tobacco smokers
    Journal of Breath Research, Volume 10, Issue 1, Pages 1-10, Feb 2016
  2. Meyer, N. A.; Root, K.; Zenobi, R.; Vidal-de-Miguel, G.
    Gas-phase dopant-induced conformational changes monitored with transversal modulation ion mobility spectrometry
    Analytical Chemistry, 2016, 88 (4), 2033-2040.
  3. Barrios-Collado, C.; García-Gomez, D.; Zenobi, R.; Ibañez, A.J.; Vidal-de-Miguel, G.; Martínez-Lozano-Sinues, P.
    Capturing in vivo plant m by real-time analysis of low to high molecular weight volatiles
    Analytical Chemistry, 2016, 88 (4), 2406-2412.
  4. García-Gómez, D.; Gaisl, T.; Barrios-Collado, C.; Vidal-de-Miguel, G.; Kohler, M.; Zenobi, R.
    Real-time chemical analysis of e-cigarette aerosols by means of secondary electrospray ionization mass spectrometry
    Chemistry – A European Journal, Volume 22, Issue 7, Pages 2452-2457, Feb 2016
  5. Barrios-Collado, C.; Vidal-de-Miguel, G.; Martínez-Lozano-Sinues, P.
    Numerical modeling and experimental validation of a universal secondary electrospray ionization source for mass spectrometric gas analysis in real-time
    Sensors and Actuators B: Chemical, Volume 223, Pages 217-225, Feb 2016

2015

  1. García-Gómez, D.; Bregy, L.; Barrios-Collado, C.; Vidal-de-Miguel, G.; Zenobi, R.
    Real-time high-resolution tandem mass spectrometry identifies furan derivatives in exhaled breath
    Analytical Chemistry, 2015, 87 (13), 6919–6924.
  2. Rawat, V.K.; Vidal-de-Miguel, G.; Hogan, C.J.
    Modeling vapor uptake induced mobility shifts in peptide ions observed with transversal modulation ion mobility spectrometry-mass spectrometry
    Analyst, 2015,140, 6945-6954.
  3. García-Gómez, D.; Martínez-Lozano, P.; Barrios-Collado, C.; Vidal-de-Miguel, G.; Gaugg, M.; Zenobi, R.
    Identification of 2-Alkenals, 4-Hydroxy-2-alkenals, and 4-Hydroxy-2,6-alkadienals in exhaled breath condensate by UHPLC-HRMS and in breath by real-time HRMS
    Analytical Chemistry, Volume 87, Pages 3087-3093, Feb 2015
  4. Vidal-de-Miguel, G.; Macía, M.; Barrios, C.; Cuevas, J.
    Transversal Modulation Ion Mobility coupled with Mass Spectrometry: Exploring the IMS-IMS-MS Possibilities of the Instrument
    Analytical Chemistry, Volume 87, Issue 3, Pages 1925-1932, Jan 2015
  5. Barrios-Collado, C.; Vidal-de-Miguel, G.
    Numerical algorithm for the accurate evaluation of ion beams in transversal modulation ion mobility spectrometry: Understanding realistic geometries
    International Journal of Mass Spectrometry, Volume 376, Pages 97–105, 15 Jan 2015

2013

  1. Criado Hidalgo, E.; Fernandez García, J.; Fernández de la Mora, J.;
    Mass and Charge Distribution Analysis in Negative Electrosprays of Large Polyethylene Glycol Chains by Ion Mobility Mass Spectrometry
    Analytical Chemistry, 2013, 85 (5), pp 2710–2716
  2. Attoui M., Paragano M., Cuevas J., Fernandez de la Mora J.
    Tandem DMA Generation of Strictly Monomobile 1–3.5 nm Particle Standards.
    Aerosol Science and Technology, 47:499511. Jan 2013

2012

  1. G. Vidal-de-Miguel, J. Fernandez de la Mora.
    Continuously Converging Multistage Focusing Lenses to Concentrate Aerosols at High Reynolds Numbers
    Aerosol Science and Technology Volume 46, Issue 3, 2012
  2. Vidal-de-Miguel, G.; Macía, M.; Pinacho, P.; Blanco, J.
    Low-Sample Flow Secondary Electro-Spray Ionization, improving vapor ionization efficiency
    Analytical Chemistry, Just Accepted Manuscript; DOI: 10.1021/ac3005378; Sep 12, 2012
  3. Attoui, M.; Fernandez-Garcia, J.; Cuevas, J.;Vidal-de-Miguel, G.;Fernández de la Mora, J.
    Charge evaporation from nanometer polystyrene aerosols
    Journal of Aerosol Science
  4. Vidal-de-Miguel, G.; Macía, M; Cuevas, J.
    Transversal Modulation Ion Mobility Spectrometry (TM-IMS), a new mobility filter overcoming turbulence related limitations.
    Analytical Chemistry, Just Accepted Manuscript; DOI: 10.1021/ac301127u; Aug 27, 2012
  5. Vidal-de-Miguel, G.; Herrero, A.
    Secondary Electrospray Ionization of Complex Vapor Mixtures. Theoretical and Experimental Approach
    Journal of the American Society for Mass Spectrometry; Volume 23, Number 6 (2012), 1085-1096, DOI: 10.1007/s13361-012-0369-z
  6. Fernández de la Mora, J.; Borrajo-Peláez, R.; Zurita-Gotor, M.
    Capillary and Coulombic effects on the gas phase structure of electrosprayed Concanavalin A ions and its clusters Cn+z (n=1-6)
    J. Phys. Chem. B 2012, 116, 9882-9898

2011

  1. Larriba, C; Hogan Jr. Christopher. J.; Attoui, M; Borrajo, R; Fernandez Garcia, J; Fernandez de la Mora, J.
    The Mobility-Volume Relationship below 3.0 nm examined by Tandem Mobility-Mass Measurement
    Aerosol Science and Technology Volume 45, Issue 4, 2011
  2. P. Martinez-Lozano, Ernesto Criado, Guillermo Vidal-de-Miguel.
    Mechanistic study on the ionization of trace gases by an electrospray plume (external link)
    International Journal of Mass Spectrometry, Dec 2011
  3. Martinez-Lozano, P.; Criado-Hidalgo E.; Vidal-de-Miguel, G.; Cristoni, S.; Franzoso, F.; Piatti, M.; Brambilla, P.
    Differential mobility analysis-mass spectrometry coupled to XCMS algorithm as a novel analytical platform for metabolic profiling
    Metabolomics, Vol 7, num 2, Jun 2011
  4. Hogan Jr. Christopher. J., Brandon T. Ruotolo, Carol V. Robinson, & Fernandez de la Mora, J.
    Tandem Differential Mobility Analysis-Mass Spectrometry of the GroEL Complex: Structure Compaction in the Gas Phase and Inelastic Air-Protein Interaction
    Journal of Physical Chemistry B, 2011 Apr 7;115(13):3614-21
  5. Fernandez de la Mora, J.
    Ionization of vapor molecules by an electrospray cloud
    International Journal of Mass Spectrometry, vol. 300, no. 2–3, pp. 182–193, Mar. 2011
  6. Hogan Jr. Christopher. J.; Fernandez de la Mora, J.
    Ion Mobility Measurements of Nondenatured 12–150 kDa Proteins and Protein Multimers by Tandem Differential Mobility Analysis–Mass Spectrometry (DMA-MS)
    Journal of the American Society for Mass Spectrometry, 2011

2010

  1. Rus, J.; Moro, D.; Sillero J. A; Royuela J.; Casado, A.; Estevez-Molinero F.; Fernández de la Mora, J.
    IMS-MS studies based on coupling a Differential Mobility Analyzer (DMA) to commercial API-MS systems
    International Journal of Mass Spectrometry, 2010, Vol. 298, Issues 1-3, pp 30-40
  2. Hogan Jr. Christopher. J.; R. Ogorzalek Loo, R; A. Loo, J; Fernandez de la Mora, J.
    Ion mobility–mass spectrometry of phosphorylase B ions generated with supercharging reagents but in charge-reducing buffer
    Phys Chem Chem Phys. 2010 Nov 7;12(41):13476-83
  3. Martinez-Lozano, P.; Rus, J.
    Separation of isomers L-Alanine and Sarcosine in urine by Electrospray Ionization and tandem Differential Mobility Analysis-Mass Spectrometry
    Journal of the American Society for Mass Spectrometry, Volume 21, Number 7, 1129-1132
  4. Hogan Jr. C.J.; Fernandez de la Mora, J.
    Ion-Pair Evaporation from Ionic Liquid Clusters
    Journal of the American Society for Mass Spectrometry, 2010

2009

  1. P. Martínez-Lozano, P. and J. Fernández de la Mora
    On-line detection of fatty acid vapors released by human skin
    Journal of the American Society for Mass Spectrometry, Volume 20, Issue 6, Jun 2009, Pages 1060-1063
  2. Martínez-Lozano, P.
    Mass spectrometric study of cutaneous volatiles by secondary electrospray ionization
    International Journal of Mass Spectrometry, Volume 282, Issue 3, 1 May 2009, Pages 128-132
  3. Fernandez de la Mora, J.
    The differential mobility analyzer (DMA): Adding a true mobility dimension to a preexisting API-MS
    Accepted for publication as a chapter in Ion Mobility Spectroscopy – Mass Spectrometry: Theory and Applications, C. Wilkins and S. Trimpin editors, Taylor and Francis, 2009
  4. Hogan Jr., C. J.; Fernández de la Mora, J.
    Tandem ion mobility-mass spectrometry (IMS-MS) study of ion evaporation from ionic liquid-cetonitrile nanodrops
    Phys. Chem. Chem. Phys., 2009
  5. Martínez-Lozano, P.; Rus, J., Fernández de la Mora; G., Hernández, M.; Fernández de la Mora, J.
    Secondary Electrospray Ionization (SESI) of Ambient Vapors for Explosive Detection at Concentrations Below Parts Per Trillion
    Journal of the American Journal for Mass Spectrometry, 2009

2008

  1. Martinez-Lozano, P. and Fernandez de la Mora, J.
    Direct Analysis of Fatty Acid Vapors in Breath by Electrospray Ionization and Atmospheric Pressure Ionization-Mass Spectrometry
    Analytical Chemistry, 2008, 80 (21), pp 8210-8215

2007

  1. Martínez-Lozano P., Fernández de la Mora J.
    Electrospray ionization of volatiles in breath
    International Journal of Mass Spectrometry, 265 (1):68-72, 2007

Congresses, Conferences and Workshops (presentations available)

The following list includes the contributions to Congresses, confs. and .w. by SEADM personnel. Publications exclusively by customers can be found in the different product pages.

2019

  1. Zamora D., Piñero-González M. Y., Pérez S., Delgado R., Amo-González M.
    [Poster] [Presentation] [Paper] Nuevas soluciones para la detección de compuestos NRBQE en contenedores.
    VII National Congress on R&D in Defence and Security, San Fernando (Spain), Nov. 2019.
  2. Perez-Lorenzo, L-J., Amo-González M.,Fernández de la Mora J.
    Multi-Electrometer Detector for Real-Time High-Resolution Measurements in Planar Differential Mobility Analyzers.
    37th AAAR Annual Conference, Portland, OR (USA), Oct. 2019.
  3. Leblanc M., Zinola S., Baltzopoulou P., Chasapidis L., Deloglou D., Melas A.D., Konstandopoulos A.G., Tejero A., Zamora D., Amo M., Rüggeberg T., Fierz M., Burtscher H.
    Measurement of Sub-23 nm particles emitted by gasoline direct injection engine with new advanced instrumentation.
    JSAE/SAE Powertrains, Fuels and Lubricants International Meeting, Kyoto, Japan, Aug. 2019.
  4. Carnicero I., McCulloch R., Martínez M.V., Piñero-González M.Y., Amo-González M.
    Atmospheric photoionization source coupled to a DMA-MS for the analysis of atmospheric non-polar contaminants.
    XXII Reunión de la Sociedad Española de Química Analítica. Valladolid (Spain), Jul. 2019.
  5. Piñero-González M.Y., Amo-González M., Ruíz L., Delgado R., Cuesta R., Fernández de la Mora G.
    Coupling D-LFSESI-DMA-MS for olive oil characterization: a novel application in food analysis.
    XXII Reunión de la Sociedad Española de Química Analítica. Valladolid (Spain), Jul. 2019.
  6. Cuesta R., Barrios-Collado C., Tejero A.
    Applications of Low Flow Secondary Electrospray Ionization for volatile characterization of biological and industrial processes.
    XXII Reunión de la Sociedad Española de Química Analítica. Valladolid (Spain), Jul. 2019.
  7. Fernández de la Mora G., Barrios-Collado C., Amo-González M.
    Fast carry-on luggage screening method for explosive detection.
    Spectrometry for Security Applications (First International Workshop). Dornbirn (Austria), Feb. 2019.
  8. Fernández de la Mora G., Amo-González M., Fernández de la Mora J.
    New GC / two-stage Differential Mobility Analyser for the screening of explosives in cargo.
    Spectrometry for Security Applications (First International Workshop). Dornbirn (Austria), Feb. 2019.

2018

  1. Fernández de la Mora G., Zamora D., Fernández de la Mora J.
    Detección de sustancias NBQRE en contenedores marítimos.
    VI National Congress on R&D in Defence and Security, Valladolid (Spain), Nov. 2018.
  2. Fernández de la Mora J.
    Cluster and protein nanoparticle studies with a bipolar electrospray source and high resolution tandem mobility analysis.
    Aerosol Technology 2018 (Plenary Session), Bilbao (Spain), Jun 2018.
  3. Amo-González M., Barrios-Collado C., Delgado R., Fernández de la Mora J.
    A DMA operating at 200⁰C for the analysis of engine exhaust nanoparticles.
    Aerosol Technology 2018, Bilbao (Spain), Jun 2018.
  4. Amo-González M., Carnicero I., Delgado R., Pérez S., Eiceman G. A., Fernandez de la Mora G., Cuesta R., Fernandez de la Mora J.
    Planar DMA: a unique instrument for high resolution nanoparticles
    analysis below 4 nm and tandem DMA analysis.

    Aerosol Technology 2018, Bilbao (Spain), Jun 2018.
  5. Baltzopoulou P., Melas A.D., Deloglou D., Vlachos D.N., Papaioannou E., de la Mora J.F., Konstandopoulos A.G.
    High-Temperature Solid Particle Emission Measurements in the Sub-23nm Mobility Size Range with the Advanced Half-mini DMA.
    Aerosol Technology Conference 2018 (AT2018), Poster TP-49, Bilbao, Spain, Jun. 2018.
  6. Papaioannou E., Melas A., Daskalos E., Zarvalis D., Vlachos N, Konstandopoulos A. G., Nicol G., Sgroi M., Zinola S., Vaglieco B. M., Di Iorio S., Barrios C., Burtscher H., Fierz M.
    Understanding and Measuring Sub-23 nm Particle Emissions from Direct Injection Engines.
    TRA Vienna, Apr 2018.
  7. Cuesta R.
    High Resolution DMA for Atmospheric Analysis.
    EMME-CARE Innovation Workshop, Paris, France, Feb. 2018.

2017

  1. Papaioannou E., Zarvalis D., Vlachos N., Konstandopoulos A.G., Nicol G., Sgroi M., Zinola S., Vaglieco M., Di Iorio S., Barrios-Collado C., Moselund P.M., Burtscher H., Fierz M.,
    Understanding and Measuring Sub-23 nm Particle Emissions from Direct Injection Engines.
    ICE2017; Capri, Italy. Sep. 2017.
  2. Fernandez de la Mora J., Amo-Gonzalez M., Barrios-Collado C., Del Castillo, J.C., Konstandopoulos A.G., Baltzopoulou P., Vlachos N.D.,
    Half-mini DMA modification for high temperature aerosols and evaluation on various combustion exhausts.
    European Aerosol Conference; Zurich, Switzerland. August (2017)
  3. Amo-González M.; McCulloch, R.; Álvaro, A.; Astudillo, A.M.; Del Castillo, J.C.; Gómez, M.; Martín J.M.
    A novel atmospheric pressure photoionization – Mass spectrometry (APPI-MS) method for the detection of polychlorinated dibenzo P- dioxins and dibenzofuran homologues in real environmental samples collected within the vicinity of industrial incinerators.
    International Journal of Mass Spectrometry, (2017), 421, 135-143
  4. Cuesta R., Barrios-Collado C., Amo-González M., Fernandez de la Mora J., Tejero A., Martinez-Lozano Sinues P.
    Low flow secondary electrospray ionization for volatile characterization delivers unique insights of biological and industrial processes.
    VIII Reunión de la Sociedad Española de Espectrometría de Masas, Barcelona , Spain, (Jun 2017).

2016

  1. Fernández de la Mora, G., Zamora D., Amo-González M., Fernández de la Mora J.
    Detecting explosive vapours in large volume freight: 2016 improvements
    Workshop on Spectrometry for security applications, Birmingham. Dec, 2016
  2. Amo-González M.; Cuesta R.; McCulloch R.
    Evaluating a Rapid Atmospheric Pressure Photoionization – Mass Spectrometry (APPI-MS) Method for the Detection of Polychlorinated Dibenzodioxins (PCDD) and Furans (PCDF) in Real Environmental Samples Collected within the Vicinity of Industrial Incinerators
    Congress Energy and Environment Knowledge Week 2016, Oct 2016
  3. Tejero, A.; Garcia Gomez, D.; Ibanez, A. J.; Martinez-Lozano Sinues, P.
    In-vivo mass spectrometric analysis of yeast growth metabolism
    Swiss Chemical Society Fall Meeting 2016, Sep 2016
  4. Amo-González, M.; Álvaro, A.; Mc Culloch, R.; Del Castillo, J.C.; Gómez, M.; Martín, J.M.; Cuesta, R.
    Evaluating a Rapid Atmospheric Pressure Photoionization – Mass Spectrometry (APPI-MS) Method for the Detection of Polychlorinated Dibenzodioxins (PCDD) and Furans (PCDF) in Real Environmental Samples Collected within the Vicinity of Industrial Incinerators
    36th International Symposium on Halogenated Persistent Organic Pollutants (Dioxin 2016)
  5. D. Zamora, M. Amo, M. Lanza, G. Fernández de la Mora, J. Fernández de la Mora
    Reaching a vapor sensitivity of 0.01 part per quadrillion (10-17 atm.) in the screening of large volume freight
    TED Workshop, Jun 2016
  6. Barrios-Collado, C. Vidal-de-Miguel, G.
    Modelling space charge effects in transversal modulation ion mobility spectrometry
    64th ASMS Conference on Mass Spectrometry and Allied Topics; San Antonio, Texas, Jun 2016
  7. McCulloch, R.; Amo, M.
    Fast detection of environmental vapors by thermal desorption – atmospheric pressure photoionization differential mobility analysis – mass spectrometry (TD-APPI-DMA-MS)
    64th ASMS Conference on Mass Spectrometry and Allied Topics; San Antonio, Texas, Jun 2016
  8. Gómez M.; Amo, M.; Cuesta R.; Del Castillo J.C.; Mc Culloch R.; Martín J.M.
    Tracking Polychlorinated Dibenzodioxin (PCDD) and Furan (PCDF) concentrations within the environment surrounding incineration facilities using Atmospheric Pressure Photoionization-Mass Spectrometry (APPI-MS)
    CEM 12th International Conference and exhibition on Emissions monitoring, May 2016

2015

  1. Barrios-Collado, C.; García-Gómez, D.; Gaugg, M.; Zenobi, R.; Vidal-de-Miguel, G.; Martínez-Lozano Sinues, P.
    Development of a comercial add-on for ultrasensitive real-time mass spectrometric analysis of vapors.
    Novartis Day, Zurich (Switzerland), Sep 2015
  2. Barrios-Collado, C.; García-Gómez, D.; Zenobi, R.; Martínez-Lozano Sinues, P.; Vidal-de-Miguel, G.
    A Universal Low-Flow Secondary ElectroSpray Ionizer: High Sensitivity Volatile Analysis on Pre-existing MS Instruments.
    Swiss Chemical Society Fall Meeting 2015, Lausanne (Switzerland), Sep 2015.
  3. Barrios-Collado, C.; Schwartz, E.; Dallmann, R.; Li, X.; Breg, L.; García-Gómez, D.; Brown, S.; Kohler, M.; Gaugg, M.; Zenobi, R.; Vidal-de-Miguel, G.; Martínez-Lozano-Sinues; P.
    Development of a real-time breath analysis platform and applications: Diagnosis in humans and drug monitoring in mice
    MSACL 2015, Mass Spectrometry: Applications to the Clinical Lab Conference; Salzburg , Austria, Sept 2015
  4. Álvaro, A.; Zamora, D.; Cuesta, R.; Amo, M.; Fernández de la Mora, G.; Fernández de la Mora, J.
    Advantages of planar DMA’s for nanoparticle studies
    EAC 2015, European Aerosol Conference; Milan, Italy; Sept 2015
  5. Macia M.; Arranz G.; A. Tejero A.; Vidal-de-Miguel G.
    Multistage transversal modulation ion mobility spectrometry: Reducing the voltage required for high resolution IMS for pre-existing mass spectrometers
    Swiss Chemical Society Fall meeting 2015; Lausanne, Switzerland; Sep 2015
  6. Macia, M.; Arranz, G.; Tejero, A.; Vidal-de-Miguel, G.
    Multistage transversal modulation ion mobility spectrometry: Enabling high transmission and high resolution IMS for trap-type MS
    International Society of Ion Mobility Spectrometry Conference; Córdoba, Spain; Jul 2015
  7. Álvaro, A.; Zamora, D.; Cuesta, R.; Amo, M.; Fernández de la Mora, J.
    Advantages of parallel plate DMA’s for studies of nanoparticles and clusters
    International Society of Ion Mobility Spectrometry Conference; Córdoba, Spain; Jul 2015
  8. García-Gómez, D.; Bregy, L.; Barrios-Collado, C.; Vidal-de-Miguel, G.; Zenobi, R.
    Real-time high-resolution tandem mass spectrometry identifies furan derivatives in exhaled breath
    XX Reunión de la Sociedad Española de Química Analítica; Santiago de Compostela, Spain; Jul 2015
  9. García-Gómez, D.; Martínez-Lozano, P.; Barrios-Collado, C.; Vidal-de-Miguel, G.; Zenobi, R.
    Identification of 2-alkenals, 4-hydroxy-2-alkenals and 4-hydroxy-2,6-alkadienals in exhaled breath condensate by UHPLC-HRMS and breath analysis in real time
    42nd Internationar Symposium on High Performance Liquid Phase Separations and Related Techniques; Geneva, Switzerland; Jun 2015
  10. McCulloch, R.; Alvaro, A.
    Coupling Atmospheric Pressure Photoionization (APPI) with Differential Mobility Analysis (DMA) – Mass Spectrometry for the detection of non-polar environmental analytes within gaseous samples
    63rd ASMS Conference on Mass Spectrometry and Allied Topics; Missouri, USA; Jun 2015
  11. Amo, M.; Alvaro, A.; McCulloch, R. Fernández de la Mora, J.
    Development of a high dynamic range differential mobility analyzer (DMA) coupled with a mass spectrometer and nano-ESI source
    63rd ASMS Conference on Mass Spectrometry and Allied Topics; Missouri, USA; Jun 2015
  12. Fernández de la Mora, G., Zamora D., Fernández de la Mora J.,
    Detecting explosive vapors in large volume freight: Experience learned from a year of sampling from the atmosphere and maritime cargo
    TED conference, Pitssburgh, PA. May, 2015
  13. Vidal-de-Miguel, G.
    Multistage transversal modulation ion mobility spectrometry
    BIT’s 4th Conference and EXPO of AnalytIX-2015; Nanjing, China, Apr 2015
  14. Vidal-de-Miguel, G.
    Add-on secondary electrospray ionizer for pre-existing MS and for high sensitivity volatile analysis
    BIT’s 4th Conference and EXPO of AnalytIX-2015; Nanjing, China, Apr 2015

2014

  1. Barrios-Collado, C.; Baertschi, C.; Zenobi, R.; Martínez-Lozano, P.; Vidal-de-Miguel, G.
    Add-on Secondary Electrospray Ionizer, delivering high ionization efficiency of vapors for pre-existing API-MS
    Swiss Chemical Society Fall Meeting 2014; Zurich, Switzerland; Sep 2014
  2. Barrios-Collado, C.; Zenobi, R.; Vidal-de-Miguel, G.
    Towards an Add-on Secondary Electrospray ionizer for pre-existing API-MS and for high sensitivity analysis of volatiles
    20th IMSC; Geneva, Switzerland; Aug 2014
  3. Álvaro, A.; Gómez, M.; Astudillo, A.M.
    Fast atmospheric dioxin detection
    2nd Iberian Meeting on Aerosol Science and Technology; Tarragona, Spain; July 2014
  4. Álvaro, A.; Fernández de la Mora, J.; Vidal-de-Miguel, G.
    Instrument for classification and analysis of suspended species through secondary electrospray ionization, mass and mobility analysis
    2nd Iberian Meeting on Aerosol Science and Technology; Tarragona, Spain; July 2014
  5. Álvaro, A.; Zamora, D.; Fernández de la Mora, G.
    Tandem DMA-MS system application to atmospheric analysis
    2nd Iberian Meeting on Aerosol Science and Technology; Tarragona, Spain; July 2014
  6. Amo, M.; Fernández de la Mora, J.
    Limits to the chemical background and the mobility-selected current transmitted in a Differential mobility analyser (DMA)
    62nd ASMS Conference on Mass Spectrometry and Allied Topics; Baltimore, USA; Jun 2014
  7. Macia, M.; Barrios, C.; Vidal-de-Miguel, G.
    Towards a functional ion mobility system for ion trap MS
    62nd ASMS conference on Mass Spectrometry and Allied Topics; Baltimore, USA; Jun 2014
  8. Rawat, V.; Hogan, C.H.; Vidal-de-Miguel, G.
    Enhanced separation capacity via Vapor Doping in Tandem Transversal Modulation IMS-MS
    62nd ASMS conference on Mass Spectrometry and Allied Topics; Baltimore, USA; Jun 2014

2013

  1. Rodriguez-Luján, I; Bailadora, G; Sanchez-Avila, C; Herrero, A; Vidal de Miguel, G.
    Analysis of pattern recognition and dimensionality reduction techniques for odor biometrics
    Centro de Domótica Integral (CeDInt-UPM), Universidad Politécnica de Madrid, Madrid, Spain & SEADM S.L., Valladolid, Spain; Aug. 2013
  2. Vidal de Miguel, G.
    Transversal Modulation Ion Mobility Seminar
    Pacific northwest national Laboratory, WA, USA, Jun 2013
  3. Criado-Hidalgo, E.; Fernández-García, J.; Fernández de la Mora, J.
    Ion Mobility Mass Spectrometry (IMS-MS) Anaysis of Globular Electrosprayed Polymer Ions Obtained via Charge Control
    61st ASMS conference on Mass Spectrometry and Allied Topics; Minneapolis, USA; Jun 2013
  4. Criado-Hidalgo, E.; Vidal de Miguel, G.; Borrajo Pelaez, R.
    On-line detection of Human Stress by Real Time Mass Spectrometric Monitoring of Skin Volatiles
    61st ASMS conference on Mass Spectrometry and Allied Topics; Minneapolis, USA; Jun 2013
  5. Vidal de Miguel, G.; Macía, M.;, Barrios, C.; Álvaro, A.
    Transversal Modulation IMS (TMIMS), Ion mobility MS: New Instrumentation & Enabling technologies
    61st ASMS conference on Mass Spectrometry and Allied Topics; Minneapolis, USA; Jun 2013
  6. Vidal de Miguel, G.; Shvartsburg, A.
    Ion Mobility Spectrometry, Introductory seminar.
    School of Industrial Engineering, University of Valladolid, Spain; Feb 2013

2012

  1. Vidal-de-Miguel, G.; Macía, M.; Cuevas, J.; Barrios, C.
    Transversal Modulation IMS. (TM-IMS) “Path to next-generation IMS: new concepts, advanced instrumentation, and leveraging the ion-molecule chemistry”
    19th International Mass Spectrometry Conference, ICMS 2012
  2. Criado, E.; Fernández García, J.; Fernández de la Mora, J.
    Low Charge State of Electrosprayed Polystyrane and other Polymer Ions, and Their Analysis by Ion Mobility Mass Spectrometry (IMS-MS)
    60th ASMS Conference on Mass Spectrometry and Allied Topics – Vancouver, Canada – May 20-24
  3. Zambrana, F.; Herrero, A.;Vidal-de-Miguel, G.; Bailador, G.; Criado, E.; Sánchez-Ávila, C.; Marquina, I.; Sereno, M.; Gómez-Raposo, C.;
    López-Gómez, M.; Merino M.; Aguayo, C; Álvarez-Gallego, M.; Garcia-Olmo, D.; Erdozain, J; Comas, C; Manceñidos, N; Feliu, J; Casado, E.
    On-line breath analysis of volatile organic compounds as a method for colorectal cancer detection
    Annual’12 Meeting of the American Society of Clinical Oncology, ASCO 2012

2011

  1. G. Vidal-de-Miguel, A. Herrero, G. Bailador, E. Criado, F. Zambrana, C. Sánchez, E. Casado.
    Towards an Online Breath Cancer Diagnostic Tool.
    Breath Analysis Summit 2011 – International Conference on Breath Research. Parma. Sep 2011
  2. G. Vidal-de-Miguel, M. Macía, P. Pinacho, J. Blanco
    Low sample flow SESI vapor ionizer
    V Reunión de la Sociedad Española de Espectrometría de Masas. Málaga. Apr 2011
  3. Criado-Hidalgo, E.; Rus, J.; Vidal-de-Miguel, G.
    Planar DMA tailored to conventional API-MS allows fast IMS-MS studies
    V Reunión de la Sociedad Española de Espectrometría de Masas. Málaga. Apr 2011

2010

  1. Hogan Jr. C.J.; Fernandez de la Mora, J.
    Mobility Measurement of Non-Denatured Protein and Protein Cluster Ions by DMA-MS
    American Society for Mass Spectrometry Conference May 2010 (ASMS 10)
  2. Hogan Jr. C.J.; Brandon Ruotolo; Carol Robinson; Fernandez de la Mora, J.
    Ion Mobility Measurement of the GroELTetradecameric Complex by Tandem Differential Mobility Analysis Mass Spectrometry
    American Society for Mass Spectrometry Conference May 2010 (ASMS 10)
  3. Fernández García, J.; Casado Rodríguez, A.; Larriba Andaluz, C.; Hogan Jr. C.J.; Brandon Ruotolo; Carol Robinson; Fernandez de la Mora, J.
    Automated Deconvolution of Complex Two-Dimensional Mass-Mobility Spectra of Multiply Charged Globular Ions into their Associated Mass-Charged Distributions
    American Society for Mass Spectrometry Conference May 2010 (ASMS 10)
  4. Larriba Andaluz, C.; Hogan Jr. C.J.; Fernández García, J.; Fernandez de la Mora, J.
    Charge-Induced break-up of Multiply Charged Poly(dimethylsiloxane) and poly(ethylene glycol) chains
    American Society for Mass Spectrometry Conference May 2010 (ASMS 10)

2009

  1. Hogan Jr., C. J.; Fernández de la Mora, J.
    Multiply Charged Ionic Liquid Nanodroplets as Mobility Standards for Tandem Ion Mobility – Mass Spectrometry
    Abstracts of the American Association for Mass Spectrometry Conference 2009 (ASMS 09)
  2. Erica Mesonero, E.; Sillero, Juan A.; Hernandez, M.; Fernandez de la Mora, J.
    Secondary electrospray ionization detection of explosive vapors below 0.02 ppt on a Triple quadrupole with an atmospheric pressure source
    Abstracts from the American Association for Mass Spectrometry Conference 2009 (ASMS 09) 59th ASMS Conference.
  3. Sillero J. A.; Rus, J.; Fernandez de la Mora J.
    Vapor detection at 1 ppt with secondary electrospray ionization (SESI) and a single quadrupole MS
    Abstract from the American Association for Mass Spectrometry Conference 2009 (ASMS 09)

2008

  1. Javaheri, H., J.C.Yves Le Blanc, Bruce Thomson, Juan Fernandez de la Mora, Juan Antonio Sillero Sepúlveda , Juan Rus.
    Evaluation of the Analytical Characteristic of a Differential Mobility Analysis coupled to a Triple Quadrupole System (DMA-MSMS)
    Abstracts of the American Association for Mass Spectrometry Conference 2008 (ASMS 08).
  2. Rus, J.; Moro D.; Sillero, J.A. ; Freixa, J.; Fernández de la Mora, J.
    A high flow rate DMA with high transmission and resolution designed for new API instruments
    Abstracts from the American Association for Mass Spectrometry Conference 2008 (ASMS 08)
  3. Martínez-Lozano, P.
    Detection of volatile metabolites of high molecular weight in urine by atmospheric pressure ionization-mass spectrometry
    Abstracts from the American Association for Mass Spectrometry Conference 2008 (ASMS 08)
  4. J. Rus, D. Moro, J. A. Sillero and J. Fernández de la Mora
    New planar DMA designs for high transmission and resolution coupling to modern API-MS instruments
    RECTA 2008, Segunda Reunión anual de la Sociedad Española de Ciencia y Tecnología de Aerosoles, Jun 2008
  5. Vidal-de-Miguel, G., Fernandez de la Mora, J.
    Impactador Virtual de Enfoque Aerodinámico con alto número de Reynolds y amplio rango
    RECTA 2008, Segunda Reunión anual de la Sociedad Española de Ciencia y Tecnología de Aerosoles, Jun 2008
  6. Fernandez de la Mora, J., Attoui, M
    Miniaturized cylindrical nano-DMA of high resolving power
    RECTA 2008, Segunda Reunión anual de la Sociedad Española de Ciencia y Tecnología de Aerosoles, Jun 2008

2007

  1. Estevez-Molinero F., Hernández M., Rus J., Casado A., Martínez-Lozano P., Fernández de la Mora J.
    APCI-MS detection of low volatility (ppt) species at room temperature: the advantage of Fenn’s droplet-based electrospray charging
    Abstracts from the American Association for Mass Spectrometry Conference 2007 (ASMS 07)
  2. Fernández de la Mora, J., Rus J., Estévez F., Sillero J.A.
    Progress in coupling a differential mobility analyzer to the source end of a mass spectrometer for IMS-MS studies
    Abstracts from the American Association for Mass Spectrometry Conference 2007 (ASMS 07)
  3. Martínez-Lozano P., Fernández de la Mora J.
    Electrospray ionization of volatiles in breath
    Abstracts from the American Association for Mass Spectrometry Conference 2007 (ASMS 07)
  4. Rus J., Estévez F., Fernández de la Mora J.
    A planar DMA coupled to a MS for tandem IMS-MS separation at high transmission, with IMS resolution approaching 100
    Abstracts from the American Association for Mass Spectrometry Conference 2007 (ASMS 07)
  • +34 687 50 31 29
  • Parque Tecnológico de Boecillo, parcela 205
    47151 Boecillo (Valladolid)
    Spain
    • Contact us
    • Subscribe

SEADM S.L. - 2022